FLAREHAWK INTERBODY FUSION SYSTEM
ENDPLATE-CONFORMING1 EXPANDABLE INTERBODY

The FlareHawk® Interbody Fusion System utilizes Adaptive Geometry™ to expand simultaneously in width, height, and lordosis after traversing the neural corridor with a small profile. Once expanded, the conformable implant is designed to reduce subsidence, restore foraminal height, and reestablish sagittal balance from a posterior approach.

Expansive Footprint, Minimal Retraction
A 17mm-wide implant can be placed with the retraction required for an 11mm implant. That’s a 55% footprint increase with no additional retraction.
FlareHawk provides multiple insertion profile and footprint options to help accommodate patient- and level-specific neural corridors.


Conformable Footprint
The multimaterial construct of the cage conforms to each patient’s endplate topography when expanded.
Coronal Conformity (TiHawk11.
Maximum Graft Delivery
Open architecture allows for continuous graft delivery through the implant and into the disc space. Up to 2cm2 of bone-graft-to-endplate contact area through the open architecture of the implant.


TITANIUM
SURFACE TECHNOLOGY
Utilizing a propriety ion beam-assisted deposition process, a uniform non-porous, 0.5-micron-thick layer of titanium is deposited through a high-vacuum, low-temperature bombardment that intermixes the titanium and PEEK atoms at the bonding interface. This process provides a strong titanium/PEEK adhesion without the loss of fluoroscopic visualization.
PEEK
Combination
The combination of PEEK + titanium may permit a modulus more similar to bone and potentially overcome concerns regarding the inertness of PEEK and limited fixation with bone. 4,5
Titanium
Roughened titanium has properties that may allow for enhanced bone fixation against surfaces.6
Uninhibited Radiographic Views
The 0.5-micron-thick layer of titanium enables the visualization of the implant components along with the ability to assess fusion with an x-ray.
Lateral Fluoroscopy (TiHawk11)


CLINICAL
OUTCOMES
RETROSPECTIVE
ANALYSIS
Bidirectional Expandable Technology for Transforaminal
or Posterior Lumbar Interbody Fusion: A Retrospective
Analysis of Safety and Performance7
129
Patients Over
Three Study
Sites
97.4%
Levels Achieving
Fusion Based on
Bridwell-Lenke
Grading
0
Reported
Device-Related
Adverse Events
- 0% Nerve Injuries
Reported - 0% Subsidence*
- 0% Endplate
Fracture Reported - 1 Case Device
Migration**
- 100% Utilized Autograft Or Allograft (No BMP Used)
- 88% Minimally Invasive Approach
58%
Patients with Clinically
Significant Improvements in
ODI
76%
Patients with Clinically
Significant Improvements in
VAS BACK PAIN
71%
Patients with Clinically
Significant Improvements in
VAS BACK PAIN
**Device migration was defined as displacement of the device relative to the position within intra-operative or immediate post-operative images.
FlareHawk For Every Approach
TLIF
Minimize the need for neural retraction by inserting an implant similar in profile to a pencil past the neural structures.
PLIF
Enables the delivery of a 34mm-wide footprint from a single-position PLIF approach.
Endoscopic Assisted
Leverage endoscopic access while providing instruments necessary for directly visualizing disc
preparation and delivering the implants.
Kambin’s Approach
With a small incision and neuromonitoring, access the disc space through Kambin’s triangle to
perform an interbody fusion.
INDICATIONS FOR USE/INTENDED USE
1. Cheng BC, Swink I, Yusufbekov R, Birgelen Michele, Ferrara L, Coric D. Current Concepts of Contemporary Expandable Lumbar Interbody Fusion Cage Designs, Part
2: Feasibility Assessment of an Endplate Conforming Bidirectional Expandable Interbody Cage. International Journal of Spine Surgery. https://www.ijssurgery.com/content/14/s3/S68. Published December 1, 2020. 2. Warburton, A., Girdler, S. J., Mikhail, C. M., Ahn, A., & Cho, S. K. (2020). Biomaterials in Spinal Implants: A Review. Neurospine, 17(1), 101–110. https://doi.org/10.14245/ns.1938296.148.
3. Ong, Y. (2015). New biomaterials for orthopedic implants. Orthopedic Research and Reviews, 7, 107–129. https://doi.org/10.2147/ORR.S63437.
4. Enders JJ, Coughlin D, Mroz TE, Vira S. Surface Technologies in Spinal Fusion. Neurosurg Clin N Am. 2020 Jan;31(1):57-64. doi: 10.1016/j.nec.2019.08.007. Epub 2019 Oct 24. PMID: 31739930.
5. Kurtz, S. M., & Devine, J. N. (2007). PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials, 28(32), 4845–4869.
6. Ratner, B. D. (2004). Biomaterials science: An introduction to materials in medicine. Amsterdam: Elsevier Academic Press.
7. Domagoj Coric, Raphael R. Roybal, Mark Grubb, Vincent Rossi, Alex K. Yu, Isaac R. Swink, Jason Long, Boyle C. Cheng and Jason A. Inzana in International Journal of Spine Surgery October 2020, 7123; DOI: https://doi.org/10.14444/7123